OM17-P4000 Force/EC
1-1
EC Force Probe
Table of Contents
Section 1
1-1 Warranty & Safety
Section 2
2-1 System Overview P4000
2-3 System Overview Electronics
Section 3
3-1 Software Installation Guide
Section 4
4-1 Field Operations Electronics
Section 5
5-1 Probe Platform Installation
5-3 Platform Operation
5-4 EC - Force Probe Operation
5-6 Soil Coring
5-8 Soil Anchoring System
5-10 Probe Removal and Tractor Installation
Section 6
6-1 Maintenance and Lubrication
6-4 Probe Removal
6-5 Case Removal
Section 7
7-1 Troubleshooting
Section 8
8-1 Specifications
Operating Instructions
Vue de la page 0
1 2 3 4 5 6 ... 32 33

Résumé du contenu

Page 1 - Operating Instructions

OM17-P4000 Force/EC 1-1 EC Force Probe Table of Contents Section 1 1-1 Warranty & Safety Section 2 2-1 System Overview P4000 2-

Page 2 - Warranty

OM17-P4000 Force/EC 3-2 Figure 2 Figure 3 Only install software in the default directory. If a different director

Page 3

OM17-P4000 Force/EC 3-3 Figure 4 Click next to install software Click finish to exit installer Figure 5 Figure 6

Page 4 - System Overview

OM17-P4000 Force/EC 4-1 Section 4 Field Operation - Electronics The Force EC probe software will acquire a EC and force measurement for every 2cm the

Page 5

OM17-P4000 Force/EC 4-2 . Place the probe tip at the desired starting point, check to ensure the GPS signal light is green and pre

Page 6 - Electronics

OM17-P4000 Force/EC 5-1 Section 5 Field Operation P4000-S Installation The P4000-S is designed to be installed in ¾ ton – 1 ton pickups and due to t

Page 7

OM17-P4000 Force/EC 5-2 5) Using the “L” straps as templates, you can drill the hole through the bottom side of the skid frame rail. Tip

Page 8

OM17-P4000 Force/EC 5-3 Field Operation Probe Platform - Start engine and allow to warm a minute or two before cycling – a few minutes if during co

Page 9 - Section 3

OM17-P4000 Force/EC 5-4 Field Operation EC - Force Probe Checking Electrical Signal Continuity and Electrode Isolation It is recommended that you r

Page 10

OM17-P4000 Force/EC 5-5 Speed Probe speed is not recommended over 30mm/sec, for optimal data resolution. This is adjustable via th

Page 11 - Click next to install

OM17-P4000 Force/EC 5-6 Field Operations Soil Coring Once you have competed probing, remove EC - Force probe as outlined in Section 6. - Install dr

Page 12

OM17-P4000 Force/EC 1-2 Warranty Veris Technologies warrants this product to be free of defects in materials and workmanship for a period of one (1)

Page 13

OM17-P4000 Force/EC 5-7 Remove sampler tube and remove cutting shoe from sampling tube by tapping and rotating, or by use of wrench (provided). (Fig

Page 14

OM17-P4000 Force/EC 5-8 Field Operations Optional Anchoring System In some field conditions it may be necessary to drive soil anchors into the soil

Page 15

OM17-P4000 Force/EC 5-9 1. Extend platform out to full extension 2. Attached chain binders on each side of probe 3. Slip anchor plates over anchors a

Page 16

OM17-P4000 Force/EC 5-10 Field Operations P4000T Removal and Tractor installation The P4000 is designed to work equally well on a tractor, or as a s

Page 17 - FOOT AND PROBE

OM17-P4000 Force/EC 5-11 Installing on Tractor – - All bushings and pins are provided for Category I and II three-point hitches. - Con

Page 18

OM17-P4000 Force/EC 6-1 Section 6 Maintenance and Lubrication Proper maintenance and lubrication of the Veris P4000G will allow you to collect high

Page 19

OM17-P4000 Force/EC 6-2 Instrument EC Signal Testing – The Veris Auxiliary Instrument is shipped with an Instrument Test Load (Part No. 10447) that w

Page 20

OM17-P4000 Force/EC 6-3 Probe EC Signal Testing – The EC – Force probe is shipped with a EC dipole tester (Part No. 29689) that will enable you to q

Page 21

OM17-P4000 Force/EC 6-4 Probe Removal This procedure is needed when removing the probe for bench top use, road transport, or for soil coring. Step

Page 22

OM17-P4000 Force/EC 6-5 Case Removal and Installation When the auxiliary case needs to be removed for storage, repair, or bench top use follow these

Page 23

OM17-P4000 Force/EC 1-3 Important! Read the following SAFETY PROCEDURES before operating the Veris P4000 • Escaping fluid under pressure can penet

Page 24

OM17-P4000 Force/EC 7-1 Section 7 Troubleshooting Troubleshooting EC module Data missing from display reading – 1. Unit must be in contact w

Page 25

OM17-P4000 Force/EC 7-2 Troubleshooting GPS If GPS fails to come in it could be for a variety of reasons. If using the provided Garmin GPS mak

Page 26

OM17-P4000 Force/EC 7-3 Fuse Replacement The fuse for the auxiliary case protects the voltage for the electrical conductivity board and the la

Page 27

OM17-P4000 Force/EC 8-1 Section 8 Specifications Max ambient temperature to operate system: 110 degrees F Max aux case temperature: 65 degrees

Page 28 - Probe Removal

OM17-P4000 Force/EC 2-1 Section 2 VERIS P4000 Probe Platform System Overview Before you begin using your P4000, it’s important to familiarize yours

Page 29

OM17-P4000 Force/EC 2-2 Hydraulic Controls All system monitoring and probe control functions are contained on the console mounted to the right of th

Page 30 - Section 7

OM17-P4000 Force/EC 2-3 Electronics System diagram Figure 5 Figures 6 The first four connections are only used with the VIS NIR probe On

Page 31

OM17-P4000 Force/EC 2-4 Figure 7&8 Figure 9 Figure 10 Probe module #38145 Cable that includes force and EC connections Garmin GP

Page 32

OM17-P4000 Force/EC 2-5 Figure 12 Figure 13 5-meter USB cable #30281 Power cable #39985 This is used to power the instrument from a vehicle

Page 33 - Section 8

OM17-P4000 Force/EC 3-1 Section 3 Software Installation and Setup Software Installation Note: For computers outside the United States of America, pl