OM17-Quad1000
1-1
Quad 1000
Soil EC Mapping System
Table of Contents
Section 1
1-2 Warranty
1-3 Safety
Section 2
2-1 Electronics Overview and Set-up: EC Surveyor
2-3 Electronics Overview and Set-up: DataLogger
2-4 Software Set-up: SoilViewer
Section 3
3-1 Implement Overview and Set-up
3-2 Additional Assembly Instructions
Section 4
4-1 Field OperationsEC Surveyor
4-2 Field OperationsEC Surveyor with DataLogger
4-4 Field OperationsEC Surveyor with SoilViewer software
4-5 Field Operations--Implement
Section 5
5-1 Troubleshooting
5-2 SoilViewer Troubleshooting
Section 6 Maintenance and Service Procedures
6-1 #1. EC Surveyor signal testing
6-2 #2. Testing electrical continuity
6-4 #3. Diagnosing and correcting EC signal problems
6-10 #4. Spring plunger testing and replacement
6-12 #5. Diagnosing GPS-related problems
6-16 #6. Firmware updates and SD card formatting
6-19 #7. Implement lubrication
6-19 #8. Maintenance
6-20 #9. Micro-chip replacement
Operating Instructions
Vue de la page 0
1 2 3 4 5 6 ... 42 43

Résumé du contenu

Page 1 - Soil EC Mapping System

OM17-Quad1000 1-1 Quad 1000 Soil EC Mapping System Table of Contents Section 1 1-2 Warranty 1-3 Safety Section 2 2-1 Electronic

Page 2 - Section 1

OM17-Quad1000 3-1 Section 3 Implement Overview and Set-up Figure 1. The tongue must be installed prior to use. To do so, please

Page 3 - Section 2

OM17-Quad1000 3-2 NOTE: Depending on shipping configuration, the unit may need additional assembly. Attach wheels as shown in Figure 3. Attach raise-l

Page 4

OM17-Quad1000 3-3 Install weight bracket if included as shown in Figure 7. A choice of assembly positions is available to accommodate customer-provid

Page 5

OM17-Quad1000 4-1 Section 4 Field Operations—Soil EC Surveyor Attach the signal cable to the quick connect coupler at front of frame, and to Signal p

Page 6

OM17-Quad1000 4-2 Field Operations—Soil EC Surveyor with Sensor DataLogger Before logging any data, make sure the SD card in the Datalogger is clear

Page 7

OM17-Quad1000 4-3 If memory card was not inserted during boot-up, the following screen will appear: Figure 8 Install card and re-start DataLogger.

Page 8

OM17-Quad1000 4-4 Field Operations—Soil EC Surveyor with SoilViewer software The EC Mapping software will automatically detect which port the Veris E

Page 9

OM17-Quad1000 4-5 Field Operations--Implement Checking Electrical Signal Continuity and Electrode Isolation It is recommended that you perform the E

Page 10 - Section 3

OM17-Quad1000 4-6 Swath width and Navigation Setting the swath width and navigation system is at the discretion of the customer. A 50’-75’ (15-23 m)

Page 11

OM17-Quad1000 5-1 Section 5 Troubleshooting EC data seem odd—jumpy, negatives, map doesn’t match known or expected soil types Perform Maintenance an

Page 12 - Install weight bracket

OM17-Quad1000 1-2 Quad 1000 Soil EC Mapping System Soil EC Surveyor Software Version 1.2 Sensor DataLogger Version 1.03 Section 1 Warranty Veris Tec

Page 13

OM17-Quad1000 5-2 SoilViewer Troubleshooting EC Surveyor is not found Check to ensure the com which the EC Surveyor is connected to is present under

Page 14

OM17-Quad1000 5-3 Reinstalling USB- Serial Converter (Part# 41377) Drivers Insert the Veris SoilViewer disk once the Veris SoilViewer appears click c

Page 15

OM17-Quad1000 6-1 Section 6 Maintenance and Service Procedure #1: EC Surveyor Instrument Signal Testing Perform this test daily or every 10 ho

Page 16

OM17-Quad1000 6-2 Procedure #2: Testing Electrical Continuity Perform this test daily or every 10 hours of data collection to ensure you are obtaini

Page 17

OM17-Quad1000 6-3 Figure 2.2 Firmly press one lead of the ohmmeter to the #1 disk blade edge (left hand, standing behind the unit) and the other l

Page 18

OM17-Quad1000 6-4 Figure 3.1 Procedure #3: Diagnosing and Correcting EC Signal Problems. Use this Troubleshooting tree to work through the system,

Page 19

OM17-Quad1000 6-5 Disk Electrode Functions- Each disk electrode on the implement is part of a pair, and each pair has a distinct function. a) Disks

Page 20

OM17-Quad1000 6-6 Coulter 2Coulter 4Coulter 3Coulter 1 Figure 3.3. Check continuity of signal harness, with o

Page 21

OM17-Quad1000 6-7 Figure 3.5 2. If ohms jump over 2 ohms when the blade is rotated, and you were careful to maintain good contact between the lead

Page 22 - Section 6

OM17-Quad1000 6-8 C. Testing Disk-Electrode isolation If continuity tests show no excessive resistance on any channel, yet erratic soil EC readings

Page 23

OM17-Quad1000 1-3 Important! Read the following SAFETY PROCEDURES before operating the Veris system: • Read and understand all instructions on saf

Page 24

OM17-Quad1000 6-9 Figures 3.10 a and b 4. Wet soil on the toolbar could be a pathway for the EC signal to short. Test disk-to-disk and disk

Page 25

OM17-Quad1000 6-10 Procedure #4 Spring Plunger adjustment and replacement The spring plungers are located in the center of each disk electrode hub ca

Page 26

OM17-Quad1000 6-11 Procedure: 1) Remove hub cap by removing the four carriage bolts. 2) If plunger is frozen in cap, remove the 3/8” nut on the o

Page 27 - Coulter 4

OM17-Quad1000 6-12 Procedure #5: Diagnosing GPS-related problems If you do not see a GPS, DGPS, or RTK in the upper left-hand corner of the EC Survey

Page 28

OM17-Quad1000 6-13 If it becomes necessary to send GPS data into your PC, you will use a program called HyperTerminal. This program is in all Windows

Page 29

OM17-Quad1000 6-14 5. The program will then ask you for a phone number. Instead of entering a phone number, specify the proper serial port number.

Page 30

OM17-Quad1000 6-15 7. At this point, upon clicking ok, legible strings of GPS data should begin appearing on the laptop screen. Here’s an example of

Page 31

OM17-Quad1000 6-16 Procedure #6: SD card formatting and firmware updates USING A VERIS SD CARD IN OTHER DEVICES CAN CAUSE FILE CORRUPTION. Insert

Page 32

OM17-Quad1000 6-17 Figure 6.2. 6. Hold the (1) key and release the RESET button. 7. If you can see the following messages, then release the (1) key

Page 33

OM17-Quad1000 6-18 9. Then you can see the following messages in sequence. Figures 6.4 a and b. 10. Do not shut off the power, but repeat from ste

Page 34

OM17-Quad1000 2-2 Figure 1. EC Surveyor kit Figure 2. DataLogger kit

Page 35

OM17-Quad1000 6-19 Procedures #7: Lubrication and #8: Maintenance Raise/lower crank: this should be lubricated on 20-hour intervals. This may vary

Page 36

OM17-Quad1000 6-20 Procedure #9: Removing EC Surveyor Cover: Microchip Replacement and Q1000 to 3150 Resistor Change It may be necessary to open th

Page 37

OM17-Quad1000 6-21 Replacing microchip. If microchip fails, or if unit needs updated firmware, it will be necessary to remove chip and replace with ne

Page 38

OM17-Quad1000 6-22 Figures 9.5 a, b, c 9a: Resistor installed for Q1000, 2000XA and 3100 models; 9b and c: position for

Page 39

OM17-Quad1000 2-3 Figure 4. EC Surveyor (rear) Figure 5. EC Surveyor (front) Figure 6. DataLogger (rear) Power port: The S

Page 40

OM17-Quad1000 2-4 Figure 7. DataLogger (front) Important – Do not allow moisture to enter the Soil EC Surveyor or Sensor Da

Page 41

OM17-Quad1000 2-5 Software Setup Figure 8. Figure 9. Figures 10a and 10b. The Veris SoilViewer software will automatically run the setup o

Page 42

OM17-Quad1000 2-6 Figure 11. Figure 12 The installer will install all necessary components Once the installer is completed, click finish

Page 43

OM17-Quad1000 2-7 Figure 13 Figure 14 Figure 15 Figure 16 The Veris SoilViewer will now install drivers necessary to operate the included U